-40%

Earth Resistance Tester Soil Resistivity Tester Ground Resistance Meter

$ 279.25

Availability: 100 in stock
  • Condition: New
  • Item must be returned within: 30 Days
  • Ground Resistance Range: 0.00Ωm~9000kΩm (automatic shifting)
  • Soil resistivity: 0.00Ωm~9000kΩm(Automatic shift)
  • Ground Voltage: AC 0~600V
  • Current Range: See description
  • Ground Resistance Resolution: 0.01Ω
  • Brand: CNYST
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Country/Region of Manufacture: China
  • Custom Bundle: No
  • LCD: 124mm×67mm(black light)
  • MPN: ETCR3000B
  • Working environment: -10℃~40℃;below 80%rh
  • Restocking Fee: No
  • Modified Item: No
  • All returns accepted: Returns Accepted
  • Features: Clamp
  • Date Storage: 300 sets
  • Close Backlight: 25mA Max

    Description

    Earth Resistance Tester Soil Resistivity Tester Ground Resistance Meter
    Product features
    ETCR3000B Earth Resistance Soil Resistivity Tester, adopts the precision 4-wire method, 3-wire method and simple 2-wire method to measure  earth resistance, earth resistance range: 0.00Ω~30.00kΩ, soil resistivity range: 0.00Ωm~9000kΩm, earth voltage range: AC 0~600V.  Import FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency. ensure the measurement of  high precision, high stability and reliability.
    ETCR3000B Earth Resistance Soil Resistivity Tester is composed of host machine, monitoring software, test wires, auxiliary ground rod and communication cable. Host machine with large LCD display, white backlight, bar chart indication, clear at a glance. It can store 300 sets of data at the same time, through the monitoring software to relize historical access and online real-time monitoring functions, dynamic display, alarm indication, with historical data reading, accessing, saving, reporting, printing and other functions
    Reference Conditions And Working Conditions
    Influence Constant
    Base Condition
    Working Conditions
    Remark
    Ambient Temp
    23℃±1℃
    -10℃-40℃
    ----
    Ambient Humidity
    40%-60%

    80%
    ----
    Working Voltage
    9V±0.1V
    9V±1.5V
    ---
    Auxiliary Earth Resistance Value

    100Ω

    30kΩ
    rC

    rP
    InterferenceVoltage
    Non

    20V
    ----
    InterferenceCurrent
    Non

    2A
    Electrode Distance of measuring R
    a

    5d
    a

    5d
    ----
    Electrode Distance of  measuring ρ
    a

    20h
    a

    20h
    ----
    Technical Specifications
    Function
    2/3/4-wire method measure earth resistance, soil resistivity; measurement of earth voltage, AC voltage
    Power Supply
    DC9V( Alkaline dry battery LR14 1.5V 6 PCS, continuous standby for 300hours )
    MeasurementRange
    Earth Resistance: 0.00Ω-30.00kΩ
    Soil Resistivity: 0.00Ωm-9000kΩm
    Earth Voltage:0V

    600V
    Measurement Mode
    Precise 4-wire, 3-wire, simple 2-wire measurement of earth resistance
    Measurement Method
    Earth Resistance: rated current change-pole method, test current 20mA Max
    Soil Resistivity: 4-pole method (Wenner method)
    Voltage to ground: average rectification(between P(S)-ES interface)
    Test Frequency
    128Hz/111Hz/105Hz/94Hz(AFC)
    Short-circuit Test Current
    AC 20mA max
    Open-circuit Test Current
    AC 40V max
    Test Voltage Wave
    Sine wave
    Electrode Distance Range
    Can be set 1m-100m
    Shift
    Earth resistance: 0.00Ω-30.00kΩ automatic shift
    Soil Resistivity: 0.00Ωm-9000kΩm automatic shift
    Backlight
    Controllable white screen backlight, suitable for dim places
    Display Mode
    4-digital super-large LCD display, white screen backlight
    Measurement Indication
    During measurement, LED flashes, LCD count down display, progress bar indication
    LCD  Dimension
    128mm×75mm
    LCD display Dimension
    124mm×67mm
    Meter Dimension
    215mm(L)×190mm(W)×95mm(H)
    Standard Test Wire
    4 wires: each for red 20m, black20m, yellow10m, and green 10m
    Simple Test Wire
    2 wires: each for red1.6mand black1.6m
    Auxiliary Ground Rod
    4 pcs: Φ10mm×150mm
    Measurement Time
    Voltage to ground: about 3 times/second
    Earth resistance, soil resistivity: about 5 seconds/time
    Measurement Times
    Over 5000 times (Short-circuit test, measurementinterval time should be at least 30 seconds)
    Line Voltage
    below AC 600V
    Communication Interface
    WithUSB interface, software monitoring, storage data can be uploaded to computer, saved or printed.
    Communication Cable
    1PCS USB communication cable, length1.5m
    Data Storage
    300 sets, “MEM” symbol storage indication,display “FULL” symbol indicate storage full
    Data Hold
    Data hold function: “HOLD” symbol display
    Data Access
    Data read function: “READ”symbol display
    Overflow Display
    Over range overflow function: “OL” symbol display
    Interference Test
    Recognize interference signal automatically, “NOISE” symbol display when interference voltage exceed 5V
    Auxiliary Ground Test
    With auxiliary earth resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
    Alarm Function
    Measurement value exceeds alarm setting value, will “Toot-toot-toot” alarm hint
    Battery Voltage
    When power voltage lower than 7.8V, display low power voltage symbol,and remind to replace battery
    Working Current
    Standby: about 20mA (Backlight shut off)
    Boot up and with backlight: about 45mA (25mA without backlight)
    Measurement: about 100mA (Backlight shut off)
    Weight
    Tester: 950g
    Test wires:1560g
    Auxiliary ground rods:935g(4pcs)
    WorkingTemperature & Humidity
    -10℃-40℃, below 80%rh
    Storage temperature & humidity
    -20℃-60℃, below 70%rh
    Overload Protection
    Measurement of earth resistance: between each interfaces ofC(H)-E

    P(S)-ES,AC 280V/3 seconds
    Insulation Resistance
    Over 20MΩ (between circuit and shell 500V)
    Withstand Voltage
    AC 3700V/rms (Between circuit and enclosure)
    Electromagnetic Features
    IEC61326(EMC)
    Suitable  Safty Standard
    IEC61010-1 (CATⅢ300V

    CAT IV 150V

    Pollution Level 2), IEC61010-031,  IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004
    Intrinsic error and performance indicators under base conditions
    Measurement Function
    MeasurementRange
    Accuracy
    Resolution
    Earth Resistance
    (R)
    0.00Ω-30.00Ω
    ±2%rdg±3dgt
    0.01Ω
    30.0Ω-300.0Ω
    ±2%rdg±3dgt
    0.1Ω
    300Ω-3000Ω
    ±2%rdg±3dgt

    3.00kΩ-30.00kΩ
    ±4%rdg±3dgt
    10Ω
    Soil Resistivity
    (ρ)
    0.00Ωm-99.99Ωm
    (ρ=2πaR a:1 m

    100m

    π=3.14)
    0.01Ωm
    100.0Ωm-999.9Ωm
    0.1Ωm
    1000Ωm-9999Ωm
    1Ωm
    10.00kΩm-99.99kΩm
    10Ωm
    100.0kΩm-999.9kΩm
    100Ωm
    1000kΩm-9000kΩm
    1kΩm
    Earth Voltage
    AC 0.0-600V
    ±2%rdg±3dgt
    0.1V
    The battery is not included in the package
    PAYMENT INFORMATION:
    1.We can accept Credit Cards,Paypal,T/T,Escrow and so on.
    2.The buyer is responsible for any tax and/or duty charged by their country.
    INTERNATIONAL SHIPPING:
    The package will be shipped by EUB DHL, FEDEX or EMS. After we shipped the parcel,we'll fill in the tracking number and inform you by e-mail.Please write the correct address and telephone number when you make orders,so the courier can contact you when they deliver the parcel to you. Thanks!
    WARRANTY INFORMATION:
    1.All the products have been checked and packed in good condition before dispatch.
    2.All the products with one year warranty.
    3.If you find any quality problems,please send it back within 3 days,and we'll send you a new one or refund you the payment after we get the returned one.
    4.Buyers have to pay for the return cost and we will pay the cost for resend
    5.All products returned should be in new conditions.